RAAC Assessments

Project Details

Breif intoduction to each project. More details to be added below.

Project Name
RAAC Assessments
Year
2023

RAAC Assessments – Utilising Thermal Imaging and Drones Surveys

Our services can quickly Detect saturation in Flat Roof and RAAC panel systems. Water ingress increases the weight load and deterioration rate of the Panels and Steel Re-Bars.

VDeterioration in RAAC can manifest in several ways:

  •  Cracks and Delamination: Moisture can infiltrate RAAC, causing cracks and delamination of the material, which weakens its structural integrity.
  • Corrosion of Reinforcement: Over time, the steel reinforcement within RAAC can corrode, further compromising its strength.
  • Surface Erosion: Exposure to the elements can lead to surface erosion, making RAAC vulnerable to further damage.
  • Loss of Insulation Properties: Deterioration can also impact RAAC’s insulating properties, leading to increased energy consumption and discomfort for occupants.

Why do we use Drones/Thermography?

Put simply, is shows us what the naked eye can’t see.
During the daytime, any moisture that has penetrated the roof system will heat up. After sunset, the surrounding areas that are dry will cool down quickly whilst the water will retain its heat and start to radiate around sunset. This method precisely shows the areas in the roof that are holding water causing leaks and weight load.
The can be cross referenced with an underside deck thermal survey. We always recommend follow up core samples are taken to confirm diagnosis.
1RAAC Drones and Thermal Imaging
2RAAC Drones and Thermal Imaging
3RAAC Drones and Thermal Imaging
4RAAC Drones and Thermal Imaging
5RAAC Drones and Thermal Imaging
6RAAC Drones and Thermal Imaging
7RAAC Drones and Thermal Imaging

Inspection Equipment

DJI MATRICE M200

Loaded with a High Resolution Visual
Camera and a Radiometric Thermal
Camera with 640×480 Resolution

Fast and Cost Effective Benefits

VP have the resources to complete multiple projects at a time with quick turnaround times, to include daytime visuals, followed by matching evening thermal images. 2-3 days later the client received a detailed analysis report indicating all defective areas including the Photogrammetry map with measured saturation areas.
This is an add on if you require area of saturated measurements.

About Visual Perspectives

In 2009 VP entered into Thermal imaging inspection services. In 2015 we introduced our Unmanned Aerial Vehicle (UAV), drone inspection and drone survey providing cost effective solutions to Building Surveyors, NHS, Construction, Portfolio Management, Universities and Education. We’re renowned for our professionalism and dedication to improving safety, mitigating risk, improving operations and reducing operating costs for our clients through the use of new technology and extensive building inspection experience.